Yes, we can provide you with a Certificate of Conformity. If you require a CofC, please include this request on your order at the time of purchase.
There are several ways to contact us. You can send us an email, give us a call (+49 (0) 6201 398 7000), or chat with us online. We’re available to answer your questions Monday through Friday from 8:30 to 17:00.
Whether you need a single PM visit or a multi-year service contract, we’ve got you covered. Contact us for more details about the service plans we offer for specific products.
We accept payment by Purchase Order, or credit card.
NBS Scientific in Almere, the Netherlands, is open on Monday to Friday from 08:30 to 17:00.
Our HQ is located in Almere, the Netherlands, at Meerpaalweg 6. The office for Germany is situated at Werderstraße 4, 69469 Weinheim.
Yes, we offer warranties on our lab equipment. Most equipment in our portfolio comes with a standard 1-year or 2-year warranty. Contact us for more detailed information on specific products.
Unfortunately we cannot easily cancel your orders, especially if it is a custom/special product.
There are several ways how to place an order. An order can be placed by sending your order to info@nbsscientific.de. You can also contact our colleagues by phone at +49 6201 398 7000 You can also create an account on our website and place an order online.
Everyone can create a webshop account via https://nbsscientific.de/en/create-an-account/. With a webshop account, you are able to order products, see prices and many more advantages. Create your free webshop account now! Please note: Your webshop account will take a couple of days to set up and once it is ready, you will receive your login details via email.
After creating your account, it may take a few days before you can use it. Our colleagues will validate your data and then send you an e-mail with the login details. Have you been waiting longer than 3 days? Then contact us!
You can't see the webshop prices because you need an account in order to see our prices. You may also try and request a quote.
Only people who have their business located in Germany are allowed to create an account on the German website.
Typically, we need as much information as possible to process an order. We need information about the company you work for: First Name Last Name Job Title Company name VAT number Invoice and delivery address Email address for order confirmations Email address for invoices. We also need a reference or order number.
If you have placed a web order, you can view it in your account. For more information about your orders by other means, please contact us at info@nbsscientific.de.
Usually 30 days from invoice date.
To view more in-depth information about shipping costs, see our terms and conditions.
Yes.
For bulk purchases, you can request a quote from Sales where discounts can be agreed upon.
If in stock the product will be delivered the next day. If we have to order the product, the expected delivery time is 4/ 6 weeks.
No this is unfortunately not possible. After the order confirmation you receive from us, you need to check everything; if something is not right report it immediately.
Our shipping method is via UPS. These are packed in a cardboard box. Sterile products are shipped in the original sterile packaging.
You can send an email with photo, then we will process it as being a complaint. Then if the complaint is justified the product will be redelivered.
If items are missing please send us an email with an explanation and possibly pictures. Our colleagues will handle it as soon as possible.
If possible, always sign for delivery.
You do not need to specifically consider something. For equipment and other fragile items, our boxes will have a "this side up" sticker. Please do not accept the box if the box is delivered the wrong way around and please make a report. For products with clean-room conditions, the clean-room bags will be shipped in a cardboard box. Please do not cut too deeply into the box to prevent the clean room bags from breaking.
It can sometimes happen that your order is delivered later than desired. This may have several causes: article not in stock, delay in shipping. We always try to keep you as well informed as possible about the delivery.
See terms and conditions.
Read moreIn case of an order of a wrong product, please contact the sales department: they will handle it further.
A capcluster has a black foil that users can remove once all tubes have been capped. A capmat has a fixed foil that cannot be removed once tubes have been capped. A capband is a capmat with perforated edges that can be torn into strips of 8 or 12 caps.
Micronic offers two methods of sterilization for their labware: gamma irradiation and ethylene oxide. If your team requires sterilization, please let us know because additional fees will apply.
Yes. We offer Tube Trial Packs for 96-well format tubes. These packs include 10 racks of tubes and 960 caps. We also offer small packs of precapped hybrid tubes and racks.
Yes. We offer samples of the following products: Micronic tubes, caps, and racks and GenTegra stability reagents. Please note: we do not have samples in stock for every product in our portfolio. If we don’t have the sample you need, we’ll do our best to send you a similar product.
We offer the full range of TPE Push Caps and Screw Caps from Micronic.
The 24-well format tubes from Micronic are compatible with the Micronic 24-well format ULT racks.
The 48-well format tubes from Micronic are compatible with the Micronic 48-well format ULT racks.
The 96-well format tubes from Micronic are compatible with the Micronic 96-well format ULT racks.
We offer the full range of 96-well, 48-well, and 24-well format sample storage tubes from Micronic.
ExpellPlus low retention pipette tips have an ultra-smooth inner surface, which reduces sample binding to the absolute minimum. Thanks to the composition of the PP material used in the production of ExpellPlus tips and the high-quality Swiss molds on which the tips are manufactured, the low binding properties of CAPP tips are achieved without the use of surface additives. ExpellPlus pipette tips are the perfect choice for volumes less than 1 ml and for all applications requiring ultimate precision.
Yes. The CP620 comes with a 1-year warranty.
No. The CP620 has a user-friendly interface that lets you select the tube size you're working with. Therefore, adapters are not needed.
The CP620 can decap an entire rack of push cap tubes in approximately 10-15 seconds, depending on tube height.
The CP620 is compatible with the following 96-well format tubes with internal thread from Micronic: 0.50ml, 0.75ml, 1.10ml, and 1.40ml.
Yes. The CP600 and CP610 come with a 1-year warranty.
To use the CP600 or CP610, simply pull out the drawer and place a rack filled with tubes on top of it. Place the capmat, capband, or capcluster on the tubes and then push the drawer closed. The unit will automatically start capping the tubes.
The CP600 and CP610 can cap entire racks of 96 tubes in approximately 7 seconds (depending on tube height).
The CP600 and CP610 can cap internal thread tubes with push caps. These caps include the TPE Capmats, Capbands, Capclusters, and EVA Capmats from Micronic.
The CP600 and CP610 are compatible with the complete range of Micronic 96-well format internally threaded tubes. This range includes the following tube sizes: 0.50ml, 0.75ml, 1.10ml, 1.40ml, 2.00ml, and 2.50ml. The CP600 can accommodate tubes up to 1.40ml (or 48mm tall) in size. The CP610 can accommodate tube up to 2.50ml (or 85mm tall) in size.
Yes. The Sigma96 can operate as a stand-alone instrument. It can also integrate into a fully-automated laboratory environment. Since users place the racks horizontally on the unit, robotic arms can more easily retrieve them.
The Sigma96 can cap, decap, or recap an entire rack of tubes in 30 seconds.
The Sigma96 is compatible with 96-well ANSI/SLAS format racks from brands like Micronic, FluidX, LVL Technologies, and Thermo Fisher. Other versions are available for 48-well format tubes and racks (Sigma48) and 24-well format tubes and racks (Sigma24).
Yes. The CS700 comes with a 1-year warranty.
The CS700 can cap and decap entire racks of tubes in less than 30 seconds.
The CS700 is compatible with ANSI/SLAS 96-well format tubes and racks from brands like Micronic, Thermo Fisher, FluidX, and LVL. Other versions are available to work with 48-well (CS710) format tubes and racks and 24-well (CS720) format tubes and racks.
Yes. The CS500 comes with a 1-year warranty.
The CS500 can cap, decap, or recap an entire row of screw cap tubes in less than 5 seconds or an entire rack in just 1 minute.
The CS500 is compatible with ANSI/SLAS 96-well format tubes and racks from brands like Micronic, Thermo Fisher, FluidX, and LVL. Other versions are available to work with 48-well (CS510) format tubes and 24-well (CS520) format tubes.
Is there a specific software you need to operate the DR700/DR710?
Yes. The DR700 and DR710 can both read and validate frozen racks of tubes.
The DR700 and DR710 rack readers use CCD imaging technology to capture the 2D Data-Matrix codes on the bottom of sample storage tubes. The DR700/DR710 side barcode reader also uses CCD imaging technology to capture 1D rack barcodes.
The DR700 and DR710 can scan a rack of tubes in 7 seconds or a single tube in 2 seconds.
The DR700 and DR710 rack readers can validate 2D Data-Matrix coded tubes. When paired with a matching side barcode reader, 1D rack barcodes can be scanned and validated as well.
Unlike the DR500, the DR505 has a passive anti-frost system that can be used to read frozen racks of tubes.
The DR500 and DR505 rack readers are compatible with 96-well, 48-well, and 24-well format tubes and racks from various brands.
The DR505 has a passive anti-frost system that can read racks of 2D coded tubes straight from the freezer.
The DR500 and DR505 rack readers can validate 2D Data-Matrix coded tubes. When paired with a matching side barcode reader, 1D rack barcodes can be scanned and validated as well.
The DR500 and DR505 rack readers use CIS imaging technology to capture the 2D Data-Matrix codes on sample storage tubes. The DR500/DR505 side barcode reader uses CCD imaging technology to capture 1D rack barcodes.
The DR500 and DR505 can scan a rack of tubes in 5 seconds or a single tube in 2 seconds.
The Micronic full-rack code readers work with the Micronic Code Reader Software.
The DR710 has an active anti-frost system that can eliminate condensation on the scanner plate. The DR700 has a passive anti-frost system that can read frozen tubes more easily.
The DR700 and DR710 rack readers are compatible with 96-well, 48-well, and 24-well format tubes and racks from various brands.
The HT500 can hold up to 20 96-well ANSI/SLAS format racks from Micronic. During each run, at least one target rack and one source rack must be specified. Contact us to learn more about the compatibility with other rack brands.
The HT500 is compatible with the following 96-well format tubes from Micronic: 0.30ml, 0.40ml, 0.50ml, 0.75ml, 0.80ml, 1.10ml and 1.40ml. Contact us to learn more about the compatibility with other tube brands.
The HT500 can pick and place up to 400 sample storage tubes per hour.
Yes. Customers can use a USB stick to load a “pick list” from a LIMS system into the HT500. The HT500 will then pick and place the desired tubes into the target rack(s). At the end of the run, users can export the rack content in a CSV file.
The HT700 can hold up to 24 96-well ANSI/SLAS format source racks and 1-3 96-well ANSI/SLAS format target racks. Because of its cassette design, the HT700 allows for short distances between the source racks and target racks. This shorter distance facilitates a faster sorting process compared to other more platform-based units.
The HT700 is compatible with the following 96-well format tubes from Micronic: 0.30ml, 0.40ml, 0.50ml, 0.75ml, 0.80ml, 1.10ml and 1.40ml. Contact us to learn more about the compatibility with other tube brands.
The HT700 can pick and place up to 550 samples storage tubes per hour.
Yes. A “pick list” generated from a LIMS system can be loaded into the HT700 via a USB stick. The HT700 will then pick and place the desired tubes into the target rack(s). At the end of the run, users can export the rack content in a CSV file.
The Lambda8 can laser-etch a variety of labware like sample storage tubes, ANSI/SLAS format rack, caps, and microscope slides. It can also laser-etch materials like aluminum, stainless steel, and titanium.
Yes. The Lambda8 can laser-etch tubes filled with samples.
Yes. The Lambda8 can laser-etch tubes straight from the freezer.
The Lambda8 can laser-etch 1 tube in approximately 1-3 seconds. Throughput depends on two things: the number of tubes in the adapter and the amount of information being etched onto each tube. Please note: the time needed to manually pick and place tubes into the adapter is not included in this approximation.
Tubes must have at least one opaque wall to be compatible with the Lambda8.
The Lambda8 only laser-etches the tube surface, so there’s no risk to the sample within the tube.
Yes. The software included with the Lambda8 is comprehensive and has the option to connect/refer to other programs and/or lists (e.g. Excel).
Since the Lambda8 "burns" into the plastic of each tube, the air must be extracted and cleaned during operation.
The Lambda576 can hold up to 6 ANSI/SLAS format racks of sample storage tubes at once.
Once the user places each rack into the Lambda576, a gripper arm selects a tube and carries it to the camera. The camera detects the laser-friendly part of the tube, and then the gripper arm positions the tube in front of the laser. The laser etches a permanent marking onto the tube, and then the gripper arm returns it to its original position in the rack. The gripper arm picks up the next tube and repeats this process for every tube in the unit.
The Lambda576 can laser etch various markings, including: 2D codes, 1D barcodes, logos, text, or sample IDs.
Tubes must have at least one opaque wall to be compatible with the Lambda576.
The Lambda576 only laser-etches the tube surface, so there’s no risk to the sample within the tube.
The software included with the Lambda576 is comprehensive and has the option to connect/refer to other programs and/or lists (e.g. Excel).
Since the Lambda576 "burns" into the plastic of each tube, the air must be extracted and cleaned during operation.
The CXT 353 can core a wide range of sample types including tissue, feces, serum, plasma, whole blood, urine, and other biofluids.
The CXT 353 can be used in several areas of research within the life science industry. Research areas include: bioanalysis to preserve biomolecular integrity, microbiome research to preserve integrity of fecal samples, molecular pathology to enhance tissue processing, and biobanking to increase sample utility and access to rare samples.
The CXT 353 works with a wide range of tubes and sample containers. Adapters can be customized to fit individual tube/container types.
The CXT 353 can extract up to 5 frozen aliquots from a single 2.00ml vial.
The LN2 tank is a 5-liter tank – it holds up to 4 liters of LN2.
Once the instrument is up to temperature, you have a working time of 1 hour before the next fill.
No. The serrated edges of the coring probe lose their sharpness after 1 core. This means that consecutive cores will become jagged and more difficult to eject.
It takes approximately 1 minute to core a sample. This includes the time it takes to hit the core bottom and then deposit the core in the destination tube.
No, the sample will not thaw inside the coring probe. Since both the probes and parent samples are kept at -80C, there is not enough time or temperature difference to thaw the partial sample during extraction.
It looks like you're coming from , is this correct?